Skip to content

omron-config ​

Sends parameter values to the selected cameras when a message arrives. The values are constants or come from the message or from the flow and global context.

The node has one input and one output.

Properties ​

PropertyDescription
NameLabel of the node in the flow. omron-config when empty
ParametersList of parameters to send. Add parameter adds a row with the parameter, its value and the source of the value
Omron ServicesState of the services on the host, with the Start Omron and Stop Omron buttons
Available CamerasThe cameras that the discovery service finds. The Select checkbox marks the cameras that this node configures

The last two panels are the ones of omron-collector and act on the same services and containers: see its Properties. A camera can be selected once it is Controlled (ours).

Parameters ​

Each row has a parameter from the list below, or Custom… with the exact name of a GenICam node of the camera. The value is a constant of the type in the table, a property of the message (msg.) or a context value (flow., global.).

ParameterValueHow the publisher applies it
Width (pixels), Height (pixels): Width, HeightNumber, in pixelsRounded to an integer, limited to the minimum and maximum of the camera and rounded down to its increment. The acquisition is paused while the value is applied
Offset X (pixels), Offset Y (pixels): OffsetX, OffsetYNumber, in pixelsAs Width and Height, without pausing the acquisition
Exposure Time (µs): ExposureTimeNumber, in microsecondsLimited to the range of the camera. The camera must have ExposureAuto set to Off
Gain (dB): GainNumber, in dBLimited to the range of the camera. The camera must have GainAuto set to Off
Acquisition Mode: AcquisitionModeText: Continuous, MultiFrame or SingleFrameThe acquisition is paused while the mode changes
Custom…Text, number or booleanThe node with that name is set according to the type of the value: a number goes to a float node, limited to its range, or to an integer node as for Width; a text to an enumeration, as the name of one of its entries, or to a string node; a boolean to a boolean node, or to an enumeration as On / Off or True / False. Command nodes cannot be executed
  • The type of the value must fit the parameter. Width, Height, OffsetX, OffsetY, ExposureTime and Gain take a number; AcquisitionMode, ExposureAuto and GainAuto take a text. The publisher refuses a value of another type, for example an exposure time that arrives as the text "22000".
  • These nine names are recognised in any letter case. Any other name must match the GenICam node exactly; a name that the camera does not have is ignored without any notice.
  • Within one message the parameters are applied in the order of their names, compared character by character: ExposureAuto comes before ExposureTime, but Gain before GainAuto, Height before OffsetY and OffsetX before Width. Switch the automatic modes off in an earlier message than the values, and send a size and its offset in separate messages when the new combination only fits the camera in one order.

Input ​

Any message makes the node evaluate its parameters and send them.

PropertyTypeDescription
msg.parametersobjectOptional. Parameter names and values that are added to the ones of the dialog and replace those with the same name. The values are text, numbers or booleans; values of other types are left out
msg.camerasarray of stringsOptional. MAC addresses of the cameras to configure for this message, in place of the selection of the dialog. Both aa:bb:cc:dd:ee:ff and AA-BB-CC-DD-EE-FF are accepted. An empty array means no camera

A parameter whose value is missing (undefined or null) is left out. A constant left empty is sent: 0 for a number, an empty text for a text. The remaining parameters are sent together to each camera.

To set the exposure and the gain by hand, the automatic modes must be off. They can be switched off with the same node, in a message of their own:

javascript
msg.parameters = {
    "ExposureAuto": "Off",
    "GainAuto": "Off"
}

The values only reach a camera whose publisher container is running. The publisher keeps the last value it received for each parameter: values that arrive while it is reconnecting to the camera are applied when the camera is back, and after every reconnection all of them are applied again, in two passes so that values that depend on each other settle. They are forgotten when the publisher container is restarted.

A new publisher waits 10 seconds before it opens its camera. Values that arrive before that are kept but not applied until the next reconnection, so send the parameters once the camera shows Controlled (ours).

Output ​

The incoming message, with the summary of what was sent in msg.omronConfig:

javascript
msg.omronConfig = {
    cameras: ["aa:bb:cc:dd:ee:ff"],        // cameras the parameters were sent to
    parameters: ["ExposureTime", "Gain"],  // names of the parameters sent
    timestamp: 1710500000000               // moment of sending, in milliseconds
}
SituationOutput
The parameters were sentThe message with msg.omronConfig
No parameter has a valueThe message, unchanged
There is no camera to configure, or the sending failsNo message

The camera does not answer: msg.omronConfig tells what the node sent, not what the camera accepted. A value that the publisher could not apply is written to the log of its container (docker logs omron-<MAC>, with the MAC address in upper case and hyphens).

Status ​

StatusMeaning
Green dot, N cams | M paramsThe node is ready, with N cameras selected and M parameter rows in its dialog (1 cam, 1 param in the singular)
Grey ring, 0 cams | M paramsNo camera is selected in the dialog
Green dot, sent K (N cams | M params)The last message sent K parameters
Yellow ring, no cameras selectedA message arrived and there is no camera to configure
Yellow ring, no parametersA message arrived and no parameter has a value
Red ring, config errorThe parameters could not be sent

Errors ​

MessageLevelCause
No cameras selected for configurationWarningA message arrived and there is no camera to configure: msg.cameras is an empty array, or it is absent and no camera is selected in the dialog
Parameter <name>: <reason>WarningThe value of a row could not be read from the message or the context. The parameter is left out
Parameter <name>: unsupported value type <type>WarningThe value of a row is not text, a number or a boolean. The parameter is left out
Parameter <name>: numeric value must be finiteWarningThe value of a row is NaN or infinite. The parameter is left out
No parameter values to applyWarningNo parameter is left to send
NATS connection failed: <reason>WarningThe NATS server could not be reached when the node started
Failed to configure cameras: <reason>ErrorA message arrived and the parameters could not be sent to the NATS server

The errors are logged without the message, so they appear in the debug sidebar and in the Node-RED log but do not trigger a Catch node.

The omron-config nodes and their dialog share one connection to NATS, opened the first time one of them needs it. If that first attempt fails it is not repeated: start the NATS server and restart Node-RED.