omron-config
Sends parameter values to the selected cameras when a message arrives. The values are constants or come from the message or from the flow and global context.
The node has one input and one output.
Properties
| Property | Description |
|---|---|
| Name | Label of the node in the flow. omron-config when empty |
| Parameters | List of parameters to send. Add parameter adds a row with the parameter, its value and the source of the value |
| Omron Services | State of the services on the host, with the Start Omron and Stop Omron buttons |
| Available Cameras | The cameras that the discovery service finds. The Select checkbox marks the cameras that this node configures |
The last two panels are the ones of omron-collector and act on the same services and containers: see its Properties. A camera can be selected once it is Controlled (ours).
Parameters
Each row has a parameter from the list below, or Custom… with the exact name of a GenICam node of the camera. The value is a constant of the type in the table, a property of the message (msg.) or a context value (flow., global.).
| Parameter | Value | How the publisher applies it |
|---|---|---|
Width (pixels), Height (pixels): Width, Height | Number, in pixels | Rounded to an integer, limited to the minimum and maximum of the camera and rounded down to its increment. The acquisition is paused while the value is applied |
Offset X (pixels), Offset Y (pixels): OffsetX, OffsetY | Number, in pixels | As Width and Height, without pausing the acquisition |
Exposure Time (µs): ExposureTime | Number, in microseconds | Limited to the range of the camera. The camera must have ExposureAuto set to Off |
Gain (dB): Gain | Number, in dB | Limited to the range of the camera. The camera must have GainAuto set to Off |
Acquisition Mode: AcquisitionMode | Text: Continuous, MultiFrame or SingleFrame | The acquisition is paused while the mode changes |
| Custom… | Text, number or boolean | The node with that name is set according to the type of the value: a number goes to a float node, limited to its range, or to an integer node as for Width; a text to an enumeration, as the name of one of its entries, or to a string node; a boolean to a boolean node, or to an enumeration as On / Off or True / False. Command nodes cannot be executed |
- The type of the value must fit the parameter.
Width,Height,OffsetX,OffsetY,ExposureTimeandGaintake a number;AcquisitionMode,ExposureAutoandGainAutotake a text. The publisher refuses a value of another type, for example an exposure time that arrives as the text"22000". - These nine names are recognised in any letter case. Any other name must match the GenICam node exactly; a name that the camera does not have is ignored without any notice.
- Within one message the parameters are applied in the order of their names, compared character by character:
ExposureAutocomes beforeExposureTime, butGainbeforeGainAuto,HeightbeforeOffsetYandOffsetXbeforeWidth. Switch the automatic modes off in an earlier message than the values, and send a size and its offset in separate messages when the new combination only fits the camera in one order.
Input
Any message makes the node evaluate its parameters and send them.
| Property | Type | Description |
|---|---|---|
msg.parameters | object | Optional. Parameter names and values that are added to the ones of the dialog and replace those with the same name. The values are text, numbers or booleans; values of other types are left out |
msg.cameras | array of strings | Optional. MAC addresses of the cameras to configure for this message, in place of the selection of the dialog. Both aa:bb:cc:dd:ee:ff and AA-BB-CC-DD-EE-FF are accepted. An empty array means no camera |
A parameter whose value is missing (undefined or null) is left out. A constant left empty is sent: 0 for a number, an empty text for a text. The remaining parameters are sent together to each camera.
To set the exposure and the gain by hand, the automatic modes must be off. They can be switched off with the same node, in a message of their own:
msg.parameters = {
"ExposureAuto": "Off",
"GainAuto": "Off"
}The values only reach a camera whose publisher container is running. The publisher keeps the last value it received for each parameter: values that arrive while it is reconnecting to the camera are applied when the camera is back, and after every reconnection all of them are applied again, in two passes so that values that depend on each other settle. They are forgotten when the publisher container is restarted.
A new publisher waits 10 seconds before it opens its camera. Values that arrive before that are kept but not applied until the next reconnection, so send the parameters once the camera shows Controlled (ours).
Output
The incoming message, with the summary of what was sent in msg.omronConfig:
msg.omronConfig = {
cameras: ["aa:bb:cc:dd:ee:ff"], // cameras the parameters were sent to
parameters: ["ExposureTime", "Gain"], // names of the parameters sent
timestamp: 1710500000000 // moment of sending, in milliseconds
}| Situation | Output |
|---|---|
| The parameters were sent | The message with msg.omronConfig |
| No parameter has a value | The message, unchanged |
| There is no camera to configure, or the sending fails | No message |
The camera does not answer: msg.omronConfig tells what the node sent, not what the camera accepted. A value that the publisher could not apply is written to the log of its container (docker logs omron-<MAC>, with the MAC address in upper case and hyphens).
Status
| Status | Meaning |
|---|---|
Green dot, N cams | M params | The node is ready, with N cameras selected and M parameter rows in its dialog (1 cam, 1 param in the singular) |
Grey ring, 0 cams | M params | No camera is selected in the dialog |
Green dot, sent K (N cams | M params) | The last message sent K parameters |
Yellow ring, no cameras selected | A message arrived and there is no camera to configure |
Yellow ring, no parameters | A message arrived and no parameter has a value |
Red ring, config error | The parameters could not be sent |
Errors
| Message | Level | Cause |
|---|---|---|
No cameras selected for configuration | Warning | A message arrived and there is no camera to configure: msg.cameras is an empty array, or it is absent and no camera is selected in the dialog |
Parameter <name>: <reason> | Warning | The value of a row could not be read from the message or the context. The parameter is left out |
Parameter <name>: unsupported value type <type> | Warning | The value of a row is not text, a number or a boolean. The parameter is left out |
Parameter <name>: numeric value must be finite | Warning | The value of a row is NaN or infinite. The parameter is left out |
No parameter values to apply | Warning | No parameter is left to send |
NATS connection failed: <reason> | Warning | The NATS server could not be reached when the node started |
Failed to configure cameras: <reason> | Error | A message arrived and the parameters could not be sent to the NATS server |
The errors are logged without the message, so they appear in the debug sidebar and in the Node-RED log but do not trigger a Catch node.
The omron-config nodes and their dialog share one connection to NATS, opened the first time one of them needs it. If that first attempt fails it is not repeated: start the NATS server and restart Node-RED.