Rate Limit Node
Purpose & Use Cases
The rate-limit node enforces a minimum interval between output messages based on external timestamps (from hardware, sensors, or other sources) rather than internal Date.now() timing. This makes rate decisions immune to event-loop drift and more accurate for real-time data streams.
Typical scenarios:
- Throttle high-frequency sensor or camera data to a manageable rate
- Deduplicate rapid-fire hardware triggers that arrive faster than processing can handle
- Control output cadence for downstream systems with rate constraints
- Monitor message timing statistics across a rolling window
Input/Output Specification
Inputs
- Incoming Message: Any Node-RED message containing a timestamp at the configured path.
Outputs
- Output 1 (passed): Messages that meet or exceed the minimum interval since the last accepted message. The first message always passes.
- Output 2 (throttled): Messages that arrived sooner than the configured interval since the last accepted message.
Both outputs send the incoming message itself, with the timing data written to the configured output path (when set; with flow or global the timing data goes to the context instead of the message).
Timing Data
javascript
{
timeBetween: number, // ms since last accepted message (-1 for first message)
avgTimeBetween: number, // average ms between messages in the rolling window (rounded)
messageCount: number // number of messages currently in the rolling window
}Configuration Options
Timestamp
- Type: Typed input (
msg|flow|global) - Default:
msg.timestamp - Purpose: Path to the external timestamp value. Accepts ISO 8601 strings, epoch milliseconds, or Date objects. A number is used as is, in milliseconds; any other value goes through
new Date(value), so epoch milliseconds must be a number, not a string ("1700000000000"is an invalid timestamp).
Interval (ms)
- Type: Typed input (
num|msg|flow|global) - Default:
250 - Purpose: Minimum milliseconds between passed messages. Messages arriving sooner are sent to the throttled output. Must be
0or more;0passes every message.
Window (ms)
- Type: Typed input (
num|msg|flow|global) - Default:
5000 - Purpose: Rolling time window for average cadence calculation. Messages older than this are dropped from the history. Must be greater than
0.
Output to
- Type: Typed input (
msg|flow|global) - Default: (empty -- no timing data attached)
- Purpose: Where to write the timing data object on each message.
Behavior
- The first message always passes (timeBetween = -1).
- Subsequent messages pass only if the external timestamp difference from the last accepted message meets or exceeds the interval.
- All messages (passed and throttled) are added to the rolling window history for cadence calculation.
- The rolling window is pruned on each message to remove entries older than the window size.
- Invalid timestamps cause the message to be dropped with the warning
Invalid timestamp: .... - Invalid interval or window values cause the message to be dropped with the warning
Invalid interval value: ...orInvalid window size: .... - Interval and window size can be set dynamically per-message when using
msg,flow, orglobaltypes. - If the timestamps go backwards (for example, the source restarts its clock), every message is throttled until a timestamp reaches the last accepted one plus the interval. Redeploying the node clears its state.
Status
- Blue dot
Idle-- No messages received yet. - Green dot
Pass: 104ms (avg 98ms)-- Last message passed. Shows time since previous and rolling average (Pass: first (avg 0ms)for the first message). - Yellow dot
Throttled: 40ms < 100ms-- Last message was throttled. Shows the interval comparison. - Red ring
Invalid timestamp,Invalid interval,Invalid windoworError.
Example Flows
Throttle Camera Frames
[Camera] → [Rate Limit: interval=100, timestamp=msg.captureTime] → [Process Frame]Accept at most one frame every 100ms based on the camera's own capture timestamp.
Monitor Sensor Cadence
[Sensor] → [Rate Limit: interval=0, output=msg.timing] → [Dashboard]Pass all messages through (interval=0) while attaching rolling timing statistics for monitoring.